Jenny Oil Fired
Combination Units demonstrate the culmination
of advanced engineering, state of the art manufacturing, and extensive steam
cleaner and pressure washer experience dating back to its inception in 1927 by
Jenny. These units combine an extensive list of standard features with rugged
strength and versatility.
The
Combination Units, like all Jenny Oil Fired units,
incorporate Jenny's Twin Fire Modular Gun Burner System featuring 18,000 Volt
Twin Electrode Ignition System, Belt Driven 6" Diameter x 4" Wide Blower System,
Adjustable Air Intake, and a Belt Driven Fuel Pump. This constant duty burner
system allows for clean and efficient combustion of Kerosene, Diesel, #2 Home
Heating Oil, or JP-4 Jet Fuel.
Since these are
Jenny Combination Cleaners, you get the
versatility of 3 cleaners in 1. With the flip of a switch, the machine can go
from a cold pressure washer to a hot pressure washer. Change the tip in the gun
and flip the machine selector switch, and the machine becomes a 325ƒF steam
cleaner.
The high performance, heavy-duty
heated units will clean any task both quickly and effectively. Pressures in the
pressure wash mode range from 750 to 3000 PSI and volumes range from 2.3 to 5.0
GPM, they will make short work of fleet, farm, and construction equipment
cleaning, light degreasing, floor and building cleaning. And if the work
warrants it, simply change the tip in the end of the gun and flip a switch and
the unit becomes a powerful steam cleaner for superior degreasing and sanitizing
ability.

Jenny Combination units are very easy to operate.
The lighted Motor, Burner, and Steam Clean Pressure Wash switches are
conveniently located and visible to the operator glowing Red In the Off position
and Green in the On position. Changing from the Pressure Wash mode to the Steam
Mode is as simple as changing a tip in the end of the gun and flipping the mode
switch. Upgrades and options are specially designed to simply bolt-on the
machine.
 
All of the machine's major system and components
are easily accessible. The entire front side of the large junction box opens to
allow entry to all the electrical components and all the electrical connections
made on our specially designed terminal board. The burner assembly can be easily
removed with three wing nuts, a tubing connection and two ignition plug wires.
The entire water control system is located on a centrally located manifold
assembly. The pump can also be easily serviced by removing three hoses and two
carriage bolts. Parts and accessories are always readily available for all Jenny
machines

Since we invented steam cleaning in 1927, quality
has been the tradition of all Jenny cleaning equipment. We use only the finest
available components, the best manufacturing methods and techniques in our state
of the art manufacturing facility, ensuring these American built machines will
pass our stringent cleaning machine standards.

Continuing our long standing tradition of
reliability, we use only the highest grade components in our manufacturing
processes. The drive system is either an industrial grade electric motor or a
high performance OHV gasoline engine. The high pressure pump is a belt driven,
oil bath, ceramic plunger pump. Jenny's specially designed Twin Fire Modular Gun
Burner system is at the very core of all our oil fired machines.

Featuring
a 5 year limited warranty, the heavy-duty, powder coated, 10 gauge steel,
modular chassis was engineered to withstand years of rugged and punishing use
and yet fit through a commercial doorway. All major components such as the fuel
tank, stainless steel float tank, coil casing, back panel, and the front panel
are bolted to the chassis.

Safety features that are standard on all Jenny
units include: 24 Volt Intrinsically Safe Control Voltage, Nozzle (or Trigger
Gun) Control, Over Pressure Protection, High Temperature Protection, and a
Ground Fault Circuit Interrupter (Single Phase Units Only).
7 Oil Fired
Combination Models Available
(shown below)
753-C - 1223-C - 1530-C - 1550-C - 2040-C -
3040-C - 3050-C
|
753-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
750 |
| Pressure
Wash - Volume-GPM |
3.0 |
| Pressure
Wash - Temperature Rise |
Up
to 140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
1-1/2 HP |
| 115 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
1 Phase with GFCI |
Optional |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Gasoline
Engine |
N/A |
| Burner
Type |
Jenny Twin Fire Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
7.7
Gallons |
| Solution
Capacity |
Separate Container |
|
1223-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1200 |
| Pressure
Wash - Volume-GPM |
2.3 |
| Pressure
Wash - Temperature Rise |
Up
to 140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
1-1/2 HP |
| 115 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
1 Phase with GFCI |
Optional |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Gasoline
Engine |
N/A |
| Burner
Type |
Jenny Twin Fire Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
7.7
Gallons |
| Solution
Capacity |
Separate Container |
|
1530-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1500 |
| Pressure
Wash - Volume-GPM |
3.0 |
| Pressure
Wash - Temperature Rise |
Up
to 140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
3 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Gasoline
Engine |
N/A |
| Burner
Type |
Jenny Twin Fire Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
7.7
Gallons |
| Solution
Capacity |
Separate Container |
| 1550-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1500 |
| Pressure
Wash - Volume-GPM |
5.0 |
| Pressure
Wash - Temperature Rise |
up
to 120°F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
5 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
Optional |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Gasoline
Engine |
11 HP |
| Burner
Type |
Jenny Twin Fire — Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
13 Gallons |
| Solution
Capacity |
Separate Container |
| 2040-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
2000 |
| Pressure
Wash - Volume-GPM |
4.0 |
| Pressure
Wash - Temperature Rise |
up
to 140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
5 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
Optional |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Gasoline
Engine |
11 HP |
| Burner
Type |
Jenny Twin Fire — Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
13 Gallons |
| Solution
Capacity |
Separate Container |
| 3040-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
3000 |
| Pressure
Wash - Volume-GPM |
4.0 |
| Pressure
Wash - Temperature Rise |
up
to 140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
7-1/2 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase |
Optional |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Gasoline
Engine |
13 HP |
| Burner
Type |
Jenny Twin Fire Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
13 Gallons |
| Solution
Capacity |
Separate Container |
| 3050-C |
Pump Output |
|
Image
Pending |
Pressure
Wash - Pressure - PSI |
3000 |
| Pressure
Wash - Volume-GPM |
5.0 |
| Pressure
Wash - Temperature Rise |
Up to 120 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Motor/Engine Horsepower |
| Electric
Motor |
10 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Gasoline
Engine |
N/A |
| Burner
Type |
Jenny Twin Fire Modular Gun Burner |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Fuel
Capacity |
13 Gallons |
| Solution
Capacity |
Separate Container |
Please contact us directly with any questions you may have
regarding our full line of Jenny Industrial and Commercial Cleaning Products
TOLL FREE - 1-877-313-8453
|

Jenny Gas Fired
Combination Units combine over 70 years of
pressure washer and steam cleaner experience with state of the art engineering
and manufacturing techniques. They comprise a wide range of standard features
using only the finest components and are built to our exacting standards. This
guarantees years of trouble free service in almost any cleaning environment. The
combination units were specifically designed for Natural or LP Gas service. The
combustion chamber was engineered to allow for the natural updraft burner system
to function at peak efficiency. The chassis features a modular construction to
allow options to be easily installed and gives quick access to all the major
components. Since these are Jenny Combination Cleaners, you get the versatility
of 3 cleaners in 1. As easy as flipping a switch, the machine can go from a cold
pressure washer to hot pressure washer. Change the tip in the gun and flip the
machine selector switch, and the machine becomes a 325ƒF steam cleaner for the
superior sanitizing and degreasing ability of a true steam cleaner. These
versatile, high performance, heavy duty stationary units will make any cleaning
quick, efficient, and effective. Pressures range from 750 to 3000 PSI and
volumes from 2.3 to 10.0 GPM in the pressure wash mode and from 70 to 300 GPH in
the steam mode. The units are ideal for cleaning all types of equipment,
machinery, and parts.

Jenny Combination Units feature simple easy to
use controls. The switches to control the Motor, Burner, and Steam
Clean/Pressure Wash are in plain view and are lighted to display the machine's
status. The switches will glow Red in the Off position and Green in the On
position. Switching modes from Pressure Wash to Steam Clean is as easy as
changing both the tip in the end of the gun and flipping the machine selector
switch.

Convenient access to all of the major system
components was designed into the machines. The large electrical junction box
houses, protects and allows for access to the entire electrical system. All
electrical connections are made through a simple specially designed terminal
board. The pump, motor, water and solution control systems are all centrally
housed underneath a large stainless steel cover. Parts and accessories are
readily available.

Quality has always been the trademark of Jenny
cleaning equipment since we invented steam cleaning in 1927. Designed and
manufactured in our state of the art facility, we use only the finest available
pumps, motors, electrical and gas components. Each piece of cleaning equipment
is thoroughly tested to guarantee that it will pass our rigorous quality
standards.

Only the highest-grade components are used in the
construction of the equipment. The industrial heavy-duty motor drives the high
performance, belt driven, oil bath, triplex, ceramic plunger pump. The
combustion system was specifically designed for Natural and LP gas applications.
It features a specially designed natural updraft combustion chamber, heat
transfer coils and gas control valves. A unique electronic ignition system is
standard to all gas fired units. It lights the gas pilot when the motor is
turned on and remains on as long as the motor runs. This allows for instant main
burner ignition when heat is required.

The
frame is a rugged, powder coated, modular chassis specifically engineered for
the gas-fired machines and features a 5-year limited warranty. All components
such as the stainless steel float tank, coil casing, back panel, and the front
panel are bolted to the chassis.

A long list of safety features that are standard
on all Jenny units include: 24 Volt Intrinsically Safe Control Voltage, Nozzle
(or Trigger Gun) Control, Over Pressure Protection, High Temperature Protection,
and a Ground Fault Circuit Interrupter (Single Phase Units Only).
10 Gas Fired
Combination Models Available
(shown below)
753-C - 1223-C - 1530-C - 1550-C - 1510-C - 1880-C - 2040-C - 2560-C - 3040-C - 3050-C
| 753-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
750 |
| Pressure
Wash - Volume-GPM |
3.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
1-1/2 HP |
| 115 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
1 Phase with GFCI |
Optional |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
|
1223-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1200 |
| Pressure
Wash - Volume-GPM |
2.3 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
2 HP |
| 115 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
1 Phase with GFCI |
Optional |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 1530-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1500 |
| Pressure
Wash - Volume-GPM |
3.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
70 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
3 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
N/A |
| 460 Volt -
3 Phase |
N/A |
| 575 Volt -
3 Phase |
N/A |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 1550-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1500 |
| Pressure
Wash - Volume-GPM |
5.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
6 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
Optional |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 1510-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
1500 |
| Pressure
Wash - Volume-GPM |
10.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
300 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
10 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 1880-C |
Pump Output |
 |
Pressure Wash - Pressure - PSI |
1800 |
|
Pressure Wash - Volume-GPM |
8.0 |
|
Pressure Wash - Temperature Rise |
140 °F |
|
Steam Cleaner - Pressure-PSI |
100-200 |
|
Steam Cleaner - Volume - GPH |
240 |
|
Steam Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
10 HP |
|
115 Volt - 1 Phase with GFCI |
N/A |
|
230 Volt - 1 Phase with GFCI |
N/A |
|
230 Volt - 3 Phase |
Standard |
|
460 Volt - 3 Phase |
Optional |
|
575 Volt - 3 Phase |
Optional |
|
Burner Type |
Jenny Electronic Gas
Burner Ignition System |
|
Fuel Type |
Natural or LP Gas |
|
24 Volt Intrinsically Safe Control Voltage |
Standard |
|
Solution Capacity |
Separate Container |
| 2040-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
2000 |
| Pressure
Wash - Volume-GPM |
4.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
6 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
Standard |
| 230 Volt -
3 Phase |
Optional |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 2560-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
2500 |
| Pressure
Wash - Volume-GPM |
6.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
180 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
10 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 3040-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
3000 |
| Pressure
Wash - Volume-GPM |
4.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
7-1/2 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase |
Optional |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
| 3050-C |
Pump Output |
 |
Pressure
Wash - Pressure - PSI |
3000 |
| Pressure
Wash - Volume-GPM |
5.0 |
| Pressure
Wash - Temperature Rise |
140 °F |
| Steam
Cleaner - Pressure-PSI |
100-200 |
| Steam
Cleaner - Volume - GPH |
110 |
| Steam
Cleaner - Temperature |
325 °F |
|
Electric Motor Horsepower |
10 HP |
| 115 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
1 Phase with GFCI |
N/A |
| 230 Volt -
3 Phase |
Standard |
| 460 Volt -
3 Phase |
Optional |
| 575 Volt -
3 Phase |
Optional |
| Burner
Type |
Jenny Electronic Gas Burner Ignition System |
| Fuel Type |
Natural or LP Gas |
| 24 Volt
Intrinsically Safe Control Voltage |
Standard |
| Solution
Capacity |
Separate Container |
|